| Sign In | Join Free | My ecer.co.uk |
|
Brand Name : COENG
Model Number : HV500
Certification : EC
Place of Origin : China
MOQ : 1
Payment Terms : L/C,T/T,Western Union
Supply Ability : 20000sets/year
Delivery Time : 10-30working days
Packaging Details : Carton, plywood case
Protection Grade : IP20
Cooling Way : Forced Air Cooling
Efficiency : 5.5kW~22kW: ≥93%; Above 30kW: ≥95%
Input Voltage : 200V (-15%) ~240V (+10%) 3Phase , 380V (-15%) ~480V (+10%) 3Phase, 500V (-15%) ~690V (+10%) 3Phase
Input Frequency : 50Hz/60Hz±5%
Output Voltage : 0V~Input voltage
Output Frequency : 0Hz~500Hz
LCD Display Panel, Support APP and hopeInsight software, Smart interconnection and monitoring, On-Line Commissioning and Debugging
The master-slave control function is primarily designed for multi-machine applications and it supports rigid and flexible connections of the drive actuator. In the rigid connection, the master control the speed and the slave control the torque. In the flexible connection, the master and the slave both can control the speed. In master-slave control mode, the external control signal is only connected to the master, which controls the slave via a serial communication link.
The VFDs are connected to the PC via optical fiber. The software has a large number of professional debugging functions, such as batch parameter settings, fault data download and waveform analysis, high-speed oscilloscope and a large number of editing functions, the software supports serial or Ethernet communication, so the software can maintain the inverter through serial communication, but also through the central control room through Ethernet maintenance of the inverter. The schematic sits as follows:

HIC200-OP-10-W is a smart operator panel developed independently for high-performance transmission products, which is informative, friendly and easy to use, and according to the different configurations of the panel, it is divided into two kinds: wiFi function and without WiFi function, which are conveniently applied to high-performance, single transmission, multi-VFDs system, it can monitor and adjust the system.
| Optional | Module | Function |
| Keyboard Base | HVKMB | Depending on the situation, the base can be installed in the specified position and the drive can be operated by operating the keyboard |
| Communication Adapter | HVCOM-USB | The drive can achieve high-speed communication with the computer via this option |
| Profibus-DP Expand Card | HVCOM-DP | It is for Profibus-DP bus communication, It can fulfill the monitoring and diagnostics of inverters |
| ABZIncremental Code disk Expansion Card | HVPG-ABZ | Code disk expansion card, incremental code disk for ABZ signal output, power programmable control, compatible single/bipolar output of the code disk |
| CANopen Expansion Card | HVCOM-CAN | It is for CANopen bus commnication, it can fulfill the monitoring and diagnostics of inverters |
| Three-phase voltage detection module | HVVMU | Detection of three-phase voltage, it can be used for permanent magnetic synchronous motor soft start grid, speed tracking and other functions |
| Technical Specification | ||
| Input/output Power | Input Uin | 200V (-15%) ~240V (+10%) 3Phase , 380V (-15%) ~480V (+10%) 3Phase, 500V (-15%) ~690V (+10%) 3Phase |
| Input Frequency | 50Hz/60Hz±5% | |
| Unbalance Degree of Uin | ≤3% | |
| Output Uout | 0V~Input Uin | |
| Output Frequency | 0Hz~500Hz | |
| Control Performance | Motor Type | Asynchronous / Synchronous |
| Control Method | V/F, OLVC (Open-Loop Vector Control), CLVC (Close-Loop Vector Control) | |
| Range of Speed Regulation | 1:10 V/F, 1:100 OLVC, 1:1000 CLVC | |
| Start Torque | VF: 100% (0.5Hz), OLVC: 150% (0.5Hz), CLVC: 180% (0Hz) | |
| Torque Precision | ≤5%, Vector Control | |
| Torque Pulsation | ≤5%, Vector Control | |
| Speed Regulation Precision | OLVC 0.2%, CLVC 0.01% | |
| Torque Response | ﹤5ms, Vector Control | |
| Dynamic Speed Reduction | OLVC<0.5%*s, CLVC<0.3%*s | |
| Acceleration and Deceleration Time | 0.0s~3200.0s, 0.0min~3200.0min | |
| Torque Lifting | 0.0%~30.0% | |
| Overload | Heavy Load Application 150% 1min/5min, Light Load Application 110% 1min/5min | |
| V/F Curve | Multiple ways: linear V/F curve, 5 kinds of torque reduction characteristic curve mode (2.0 power, 1.8 power, 1.6 power, 1.4 power, 1.2 power), user-defined VF curve | |
| Input Frequency Accuracy | Digital: 0.01Hz, Analog: 0.01Hz | |
| Control Performance | Acceleration and Deceleration Curve | Straight, S Curve |
| Multiple Speed-Steps Operation | 16-Speed Steps Operation through control terminals | |
| Automatic VoltageAdjustment (AVR) | Keeping the output voltage constant automatically when the grid voltage changes within a certain range | |
| Fixed Length | Setted and Fixed Length Control | |
| In-build PID | It Can Easily Constructed Closed loop control system | |
| Enhencement Function | Free Function Block | |
| Input/output Power | Set Frequency | Keyboaed, UP/DOWN Terminals, Multiple Speed-Steps Operation, Terminals Pulsation, Com |
| Analog Input Terminals | AI1: 0V~10V/-10V~10V, AI2: 0V~10V/0(4) mA~20mA | |
| Digital Input Terminals | DI1-DI6, 6 programmable digital input terminals, optocoupler isolation, compatible with drain/source input | |
| Digital Input/Output Terminals | DIO1: Fast pulse output, normal input/output; DIO2: fast pulse input, normal input/output | |
| Anolog Output Terminals | 2 Strings 0V~10V/0 (4) mA~20mA | |
| Relay Output | 2Strings Contact Type FormC | |
| Motor Temperature Detection | Support PT100/PT1000/KTY84 | |
| STO Interface | SIL3/PLe Safe torque shutdown function | |
| Com | Com Protocol | Modbus RTU (Standard), Pro ibus, CANopen, pro inet, Devicenet, Ethercat |
| Environment | Altitude | Without Derating Operation Within 2000m Altitude; 2000m~4000m, Each 100m lifting, Derating 1% (Current) |
| Operation Temperature | -25℃~+40℃ (40℃~55℃ Derating) | |
| Humidity | 15%~95%, Without Condensation | |
| Vibration | 3M3, IEC60721-3-3 | |
| Storage Temperature | -40℃~+70℃ | |
| Operation Place | Indoor, Without direct sunlight, no flammable, corrosive gases, liquids and conductive particles | |
| Accessory | Encoding card, communication expansion card, voltage detection card | |
| Protection Function | Short circuit, over current, overload, over voltage, under voltage, phase loss, over temperature, external fault, etc. | |
| Efficiency | 5.5kW~22kW: ≥93%; Above 30kW: ≥95% | |
| Installation Method | Cabinet | |
| Protection Degree | IP20 | |
| Cooling | Forced Air Cooling | |
Saudi Arabia
Withstand extreme heat (up to 55°C with derating) using the HV500’s forced air cooling and robust enclosure. The drive’s STO interface and high start torque support Saudi Arabia’s oil and gas sector, ensuring safety and efficiency.
United Arab Emirates
Leverage the HV500 for HVAC and building automation in the UAE’s urban projects. Features like PID control and Modbus RTU enable smart building integration, while the wide voltage range adapts to local grid variations.
Singapore
Enhance precision in Singapore’s electronics and pharmaceutical industries with the HV500’s 0.01Hz frequency accuracy and SIL3 safety. Its compact design and communication protocols like PROFINET support Industry 4.0 initiatives.
Malaysia
Address high humidity and temperature with the HV500’s condensation-free operation and derating capabilities. The drive’s easy programming and multiple digital inputs (DI1-DI6) suit Malaysia’s diverse manufacturing landscape.
|
|
Humidity and Vibration Tolerant VFD (15%~95% Humidity, 3M3 Vibration) for Harsh Conditions Images |